SC Protect Filters


Protect

Using sophisticated adsorption media, the Protect systems have been designed to help industries comply with a mountain of increasingly stringent environmental legislation on emissions, both liquid and vapour phases.

Activated carbon adsorption is the fundemental technology of the Protect system. Contaminants are attracted to the activated carbon surfaces by intermolecular attraction.

Each Protect adsorption unit has an internal distribution system to ensure extended and efficient contact between the vapour or liquid and the activated carbon.


SC PROTECT Filter Units

Product Versatility
  • Protect V range is for treating vapour streams.
  • Protect L is for liquids.
Both are available, generally ex-stock, in 200, 1000 and 2000 litre sizes. All units offer proven design, rugged construction and negligible supervision requirements. Installation is rapid, with forklift fittings provided for easy handling.

Custom Design Services
Adsorption units can be specifically designed to incorporate pressure vessel requirements, particulate filters, monitoring and control equipment, as well as skid mounted assemblies and units using specialist impregnated carbons. Alternative materials of construction are available to order.

APPLICATIONS
  • Protect V controls emissions from storage tank and process vents, air stripper exhausts, soil vapour extraction systems and all general emission/odour sources.

SC PROTECT L2000s
  • Protect L removes contaminants from waste water, ground water, potable water, process and product streams.

EXAMPLES OF
TYPICAL CONTAMINANTS

Alcohols
Aldehydes
Ammonia & Amines
CFCs
Chlorinated Hydrocarbons
Fuel Oils
Hydrocarbons
Hydrogen Sulphide
Industrial Cleaning Solvents


Ketones
Mercaptans
Nuisance Odours
PCBs
Pesticides & Herbicides
Phenoloic Compounds
Sulphur Dioxide


HIGH FLOW

MODEL NO:

V1

V2

V3

V4

Overall Height (mm)
Diameter (mm)
Inlet/Outlet Standard (mm)
Carbon Mass (kg)
Maximum Air Flow (m³/hr)

1150
1000
200
250
3000

1500
1350
300
475
6000

1700
1800
400
800
10000

2200
1800
500
1100
15000

High Flow Units

Annular bed adsorbers for High Flow, low pressure drop applications capable of handling vapour phase flows ranging from 3000 to 15,000 m³/hr with a typical pressure drop of 150 mm w.g.

VAPOUR PHASE

MODEL NO:

V200

V1000

V2000

Maximum Flow Rate (m³/hr)
Height (mm)
Diameter (mm)
Gross Weight (kg)
Maximum Pressure (bar g)

250
900
580
120
0.5

1250
1850
1300
850
0.5

1250
2600
1300
1450
0.5

Standard Connections
materials of Construction

* Non-standard connections can be made to order

2" BSP
Carbon Steel/
Stainless Steel/
Polyethylene

4" or 6" Flange
Carbon Steel/
Stainless Steel

4" or 6" Flange
Carbon Steel/
Stainless Steel

SC Filter Unit - Diagrams
SC PROTECT V200 Pressure Drop Chart SC PROTECT V1000 & V2000 Pressure Drop Chart
LIQUID PHASE

MODEL NO:

L200

L1000

L2000

Maximum Flow Rate (m³/hr)
Height (mm)
Diameter (mm)
Gross Weight (kg)
Maximum Pressure (bar g)

1.5
900
580
120
0.5

10
1850
1300
850
0.5

20
2600
1300
1450
0.5

Standard Connections
materials of Construction

* Non-standard connections can be made to order

2" BSP
Carbon Steel/
Stainless Steel/
Polyethylene

4" or 6" Flange
Carbon Steel/
Stainless Steel

4" or 6" Flange
Carbon Steel/
Stainless Steel

SC PROTECT L200 Pressure Drop Chart SC PROTECT L1000 & L2000 Pressure Drop Chart

Pressure drop information shown here has been calculated from a regular grade of activated carbon, under standard conditions. Actual values may vary depending on the operating conditions.

   request a quotation on-line On-line request for quotation

Application Data

SC Protect filter systems are effective for the control of odours and toxic gas, as well as VOC emissions, from both the liquid and gaseous phase of a variety of process output streams. The links below form a valuable cross reference of useful application data.
Carbon Adsorption
Characteristics Table


Carbon Absorption Characteristics Table
Air Treatment
Suitability Table
Air Treatment Suitability Table
Liquid Treatment
Suitability Table